Guru Hub 3 Core approved meter list
Guru Hub 3 Core manages and monitors up to 4 utilities by directly connecting to wired mbus meters. It can also control up to 2 external control devices, such as shut-off valves, and can integrate into HIUs or heat pumps via Modbus.
Hub 3 Core Details: M-Bus - 1 input with up to 4 meters. Modbus - 1 input/output. Relay outputs - 2.
Find out more about the Guru Hub 3 Core on our website. Or download our brochure directly
Meters which are connected to the Hub 3 Core must support a baud rate of 2400 in order to be read.
Mbus Heat Meters
| Approved by Guru | Caveats | Default mbus address |
Zenner Zelsius C5
| Fully Approved | None | mbus/0 |
Sontex Superstatic 449
| Fully Approved | None | mbus/0 |
Kamstrup Multical 601
| Fully Approved | None | Last 2 digits of the serial number of the meter where the last 3 digits are less than 250 otherwise the last 3 digits |
Kamstrup Multical 602
| Fully Approved | None | Last 2 digits of the serial number of the meter where the last 3 digits are less than 250 otherwise the last 3 digits |
Kamstrup Multical 603
| Fully Approved | None | Last 2 digits of the serial number of the meter where the last 3 digits are less than 250 otherwise the last 3 digits |
Kamstrup Multical 403
| Fully Approved | None | Last 2 digits of the serial number of the meter where the last 3 digits are less than 250 otherwise the last 3 digits |
Evinox Mod RC15
| Fully Approved | None | mbus/0 |
Itron CF Echo II
| Fully Approved | None | mbus/0 |
Landis+Gyr T230 Ultraheat / Ista T 230 Ultego III Smart
| Fully Approved | None | mbus/0 |
Engleman US2
| Fully Approved | None | mbus/0 |
Engelmann SensoStar U S3
| Fully Approved | None | mbus/0 |
Danfoss Sonometer 1000
| Fully Approved | None | mbus/0 |
Danfoss Sonotometer 1100, Sharky 775, Rossweiner Ultrasonic
| Fully Approved | None | Old generation meters are mbus/0, new models are the last two digits of the serial number |
Mbus Cooling Meters
| Approved by Guru | Caveats | Default mbus address |
Axioma Qualsonic E3
| Fully Approved | None | mbus/0 with the cooling registers from the mbus frame |
Itron CF Echo with cooling tariff
| Fully Approved | None | mbus/0 |
Mbus Water Meters
| Approved by Guru | Caveats | Default mbus address |
Maddelena Evo
| Fully Approved | None | mbus/0 |
Mbus Electric Meters
| Approved by Guru | Caveats | Default mbus address |
Inepro PRO1
| Fully Approved | None | mbus/0 |
Dual Utility Meters
| Approved by Guru | Caveats | Default Modbus address |
Axioma Qualsonic
| Fully Approved | None | last two digits of the serial number with the appropriate registers from the mbus frame |
Itron CF Echo with cooling tariff
| Fully Approved | None | mbus/0 |
ModBUS supported devices
| Approved by Guru | Caveats | Default Modbus address |
Altecnic SATK32
| Fully Approved | None | Address 1 |
Pulse to mbus converters
| Approved by Guru | Caveats | Default mbus address |
IZAR Port Pulse Mini
| Fully Approved | None | The address is dependent on what is set in the IZAR software - to utilise both mbus outputs the correct registers should be used. |
If the meter you wish to use is not listed above, then please email support@gurusystems.com to discuss how we can test this for you.